■ Using Command Block and Status Words (
)
You can use the command flag setting in Command Block to request the panel to
set the current recipe number, read a recipe from a PLC or write a recipe to a
PLC. You can also receive current the recipe block ID or current recipe number
by checking the related status word and specifying the word variable in Status
Words. For details, please see
Section 3.6 Command Block
and Status Words.
To change the current recipe number, the PLC first sets the Parameter Two
Register to the desired recipe block and the Parameter One Register to the
desired recipe number, then turns on the Set Current Recipe Number (#2) command
flag. Also, $RNm (Current Recipe Number Register, m: Recipe Block ID) of the
panel can be changed by the PLC.
To update a recipe in the panel, the PLC first sets the Parameter Two Register
to the desired recipe block and the Parameter One Register to the desired recipe
number, then turns on the Read Recipe From PLC (#3) command flag. The panel
reads data in the Recipe Block to update the specified recipe in the panel.
To receive a recipe, the PLC first sets the Parameter Two Register to the
desired recipe block and the Parameter One Register to the desired recipe
number, then turns on the Write Recipe To PLC (#4) command flag. The panel sends
the specified recipe data to the Recipe Block in the PLC.
Note: You do not need to specify the recipe block if the
application has only one recipe block.
Note: To make the above operation work, the specified recipe
block must exist, or else the panel ignores the request. The specified recipe
number in the Parameter One Register must be between 0 and the maximum recipe
number - 1.If the Parameter One Register is greater than or equal to the maximum
recipe number, the panel ignores the request.
■ Using the Function Button (
)
You can use a function button to write the current recipe to the controller, or
update current the recipe by reading the recipe from the controller. For
details, please see
Section 5.4.1 Basic Operations
of function buttons.
Source.Section 11.4.4 of the PM Designer Software User Manual, Edition 2.0, © Cermate Technologies Inc. (www.cermate.com, service@cermate.com). Reproduced online, with the manual's own figures, by TSL Automation Solutions, authorised Cermate distributor, for users of Cermate HMI panels. PM Designer and PanelMaster are trademarks of Cermate Technologies Inc.
Text and figures are the manufacturer's and may describe features your panel or software version does not have. For a plain-language introduction read the PM Designer guide; for help with a specific panel contact TSL Automation.